1. Brief Introduction
It is regarded as special filtration device for nuclear facility pollution control. The purpose is to purify local space air inside the nuclear facility, and prevent radioactive aerosol diffusion. It is also applied for purifying polluted air caused by corrosive gas for nuclear industry.
When operation, polluted gas pass into medium filter and hepa filter in turn. Finally radioactive aerosol or corrosive particle is blocked on filter surface. The filtered air can meet nuclear safety discharge standard.
2. Performance and Index
Air volume:700m³/h
Power:2.2KW
Voltage:380V, 3phase,50Hz
Max negative pressure:6400Pa
Filter class: Level II (medium +hepa)
Medium filter:
Filter class:≥F7(80≤Em<90,EN779:2002)
Hepa filter:
Filter class: ≥ H13(99.95%,EN1822:2009)
Noise level:≤78dB
Dimension:750x750x1060mm
Weight:145Kg
3. Characteristic
With inlet and outlet nozzle, easy to connect with other facility
Easy operation, easy to lift and move on stable platform, braking fuction
Low noise centrifuge fan, seal tightly, stable inner negative pressure
2-level filters, more safety and efficiency, meet nuclear safety discharge standard
Anti-corrosion painting inside, anti-corrosive material for filter house, suitable for severe service
Easily for installation, disassembly and packing (plastic bag packing )
Indicator light show working status
Indicate filter pressure drop to guide operator know filter service cycle.